Turboclean Dairy RO Element Specification Sheets, using the ACM™ Reverse Osmosis Membranes, a fully aromatic, polyamide, thin film composite membranes. TriSep’s ACM™ series provides high quality permeate flow, high salt rejection, and constant low operating pressures while meeting USDA and FDA guidelines.

Applications

  • Whey concentration
  • Lactose and UF permeate concentration
  • Whole / Skim Milk Concentration
  • Evaporator Condensate recovery
  • Rinse water recovery
  • RO permeate polishing
  • Other food and pharmaceutical concentration
  • Food and pharmaceutical waste water

Membrane Characteristics and Operation Limitations

ACM2: High rejection, fully aromatic, polyamide thin film composite membrane on polyester backing

Operating Conditions and limitations

  • Maximum element feed pressure 600 psi (41 bar)
  • Typical element feed pressure 100 -400 psi (7-28 bar)
  • Maximum operating temperature 122º F (50ºC)
  • pH range continuous operation 2 – 11
  • pH range cleaning 2 – 11.5 @ 140ºF (60ºC)
  • Maximum chlorine concentration <0.1 ppm

Water Quality for cleaning and Diafiltration

  • Maximum SDI 5.0
  • Turbidity 1 NTU (15 minute test)

Other oxidizing agents and chemical limitations:

Consult the local TriSep representative

Application

Element

Element

Size

Code

Whey

31 Mill

3838/3840

M2D7U8

46 Mill

3838/3840

M2D7V6

65 Mill

3838/3840

M2D7X3

Whey

31 Mill

8038

M2D7U8

46 Mill

8038

M2D7V6

65 Mill

8038

M2D7X3

Milk

31 Mill

3838/3840

M2D2U8

46 Mill

3838/3840

M2D2V6

65 Mill

3838/3840

M2D2X3

Milk

31 Mill

8038

M2D2U8

46 Mill

8038

M2D2V6

65 Mill

8038

M2D2X3

Lactose

31 Mill

3838/3840

M2C9U8

46 Mill

3838/3840

M2C9V6

Lactose

31 Mill

8038

M2C9U8

46 Mill

8038

M2C9V6


 

TriSep Corporation

93 S La Patera Ln . Goleta Ca 93117 U.S.A
      Email:info@trisep.com Tel:(805)-964-8003 - Fax: (805)-964-1235

©2006, TriSep Corporation, all rights reserved. WebSite created by DHK Graphics™